A: straight swap
Say a 2,000 sq ft Plano house with a 200 A panel and tight ducts replaces an old AC and furnace with a ducted heat pump.
$6,500–$14,500 (DFW band).
Cost guide · heat pumps
A ducted heat pump in Dallas–Fort Worth is published at $6,500–$14,500 installed in 2026, from two DFW sources. Because it replaces both the AC and the furnace, compare it with a full-system quote ($8,000–$16,000 published DFW), not an AC alone. Panel work, ducts and backup heat decide where in the band your house lands.
Published installed heat pump ranges, 2026
| Item | Range | Note |
|---|---|---|
| Ducted heat pump, DFW | $6,500–$14,500 | Two DFW sources, all sizes |
| 3-ton heat pump, Dallas | $6,000–$8,000 | HVAC.com, page dated May 2024 |
| 2-ton, national | $3,500–$8,000 | PickHVAC, Midwest labor |
| 3-ton, national | $4,200–$9,500 | PickHVAC, Midwest labor |
| 4-ton, national | $5,200–$11,500 | PickHVAC, Midwest labor |
| 5-ton, national | $6,000–$13,500 | PickHVAC, Midwest labor |
| Full AC + furnace, DFW | $8,000–$16,000 | The like-for-like alternative |
Few sources publish Dallas heat pump prices, and they publish them as one band for all sizes. The Dallas 3-ton figure is older (May 2024) and is shown for orientation. Every number on this page names its source and date; none is our quote, and the editorial policy explains why we publish no figure of our own yet.
The only size-by-size heat pump figures we found are national. Read them next to the DFW central AC range for the same size, which the same houses usually start from.
| Size | Heat pump, national | Central AC only, DFW | Oncor 2026 cap |
|---|---|---|---|
| 2 ton | $3,500–$8,000 | $7,500–$15,000 | $2,000 |
| 3 ton | $4,200–$9,500 | $5,500–$16,500 | $2,600 |
| 4 ton | $5,200–$11,500 | $7,500–$18,500 | $3,200 |
| 5 ton | $6,000–$13,500 | $7,500–$20,000 | $3,400 |
National heat pump rows: PickHVAC (page dated 2026-05-22), Midwest labor assumption. AC column: DFW contractor and cost pages on the cost guide, not including a furnace. Oncor caps: 2026 HEE SOP manual §3.2; a cap is a maximum per system, not a payment.
Size comes from a Manual J load calculation for both heating and cooling. In DFW the cooling load usually sets the size; see what size AC a Dallas home needs.
A heat pump does two jobs, so the fair comparison depends on the furnace you have.
| Your furnace | Compare the heat pump with | Published range |
|---|---|---|
| Old, due for replacement | Full system: AC + furnace (DFW) | $8,000–$16,000 |
| Old, Dallas page | AC + gas furnace (Dallas) | $6,000–$13,800 |
| Young and sound | AC only, 3 ton (DFW); or heat pump on the furnace (dual fuel) | $5,500–$16,500 |
| None (all-electric) | Like-for-like AC with electric strips | No separate published figure |
The overlap is the answer
The DFW heat pump band and the DFW full-system band overlap almost entirely. Equipment price rarely decides it; the panel, the backup heat plan, your gas service and your utility rates do. The AC and furnace guide walks through the furnace decision.
| Item | Published range | Area | When it applies |
|---|---|---|---|
| Panel upgrade, 100 A to 200 A | $1,800–$3,500 | National | Backup heat pushes an older service past capacity. A new meter base or service riser adds $500–$1,000. |
| Duct sealing or repair | $1,300–$8,000 | Dallas | Leaky attic ducts lose heated air in winter as well as cooled air in summer. |
| New ductwork, about 2,000 sq ft home | $6,000–$7,000 | Dallas (May 2024) | Ducts damaged or badly undersized. |
| Smart thermostat, installed | $120–$450 | National | The old thermostat cannot control a reversing valve and stage backup heat. |
Backup heat size is the hidden cost driver. More kilowatts of strip heat need a bigger circuit and may trigger the panel upgrade; dual fuel with an existing furnace avoids most of that load. The trade-offs are on the heat pump installation page. In the February 2021 winter storm DFW Airport fell to -2 °F on 16 February and stayed at or below freezing for about 139 hours (13–19 February).
Hypothetical houses built only by adding published ranges. They show how scope moves the total; they are not estimates for a real house.
Say a 2,000 sq ft Plano house with a 200 A panel and tight ducts replaces an old AC and furnace with a ducted heat pump.
$6,500–$14,500 (DFW band).
Say a 1970s Garland house on a 100 A panel needs 200 A to carry the backup heat.
$8,300–$18,000 (DFW band plus national panel range).
Say a Mesquite house has leaky attic ducts that a test confirms.
$7,800–$22,500 (DFW band plus Dallas duct range).
Budget B mixes DFW and national figures, so treat it as the loosest. Ask whether a smaller backup strip or dual fuel would avoid the panel work before accepting it.
Garland and CoServ customers, and the full rules, are on Dallas AC rebates by utility. National heat pump rebate context is on our sister site, HyreHVAC.
Put two or three quotes side by side in the quote comparison tool.
Installed price is only half the comparison. Running cost depends on your electricity and gas rates, the heat pump’s HSPF2, the furnace’s AFUE and how often backup heat runs. No published Dallas figure fits every rate plan, so this page does not offer one. Enter your own rates in the heat pump vs AC calculator, and read heat pump vs gas furnace in North Texas for the freeze question.
Then check the license on the TDLR lookup.
Two DFW sources publish a ducted heat pump at $6,500–$14,500 installed in 2026. A Dallas page from May 2024 puts a 3-ton heat pump and air handler at $6,000–$8,000. Size-by-size figures are national only.
The published bands overlap: $6,500–$14,500 for a heat pump against $8,000–$16,000 for a DFW full system. The deciding costs are usually the panel, backup heat and ducts.
Oncor’s 2026 program pays participating service providers for high-efficiency heat pumps installed for Oncor customers, capped by tonnage (for example $2,600 at 3 tons). The amount reaches you through the contractor and is not final until Oncor approves the report.
No. The federal 25C credit applied to property placed in service before 31 December 2025.