Choosing a system
R-410A vs the new refrigerants
New AC equipment made since 1 January 2025 uses R-454B or R-32, lower-GWP "A2L" refrigerants, instead of R-410A. After an EPA rule effective 27 July 2026, contractors may still install pre-2025 R-410A systems until that stock runs out. Either can be a sound purchase; ask which one you are quoted and get it in writing.
On this page (15)
- At a glance
- What changed, in plain terms
- The refrigerants you will see on quotes
- What "A2L" means, and whether it should worry you
- R-410A stock or a new A2L system: how to choose
- What the refrigerant change does to price
- The coil and line-set questions
- If you still have an R-22 system
- Living with your choice: service over the years
- Scenario: two quotes, two refrigerants
- Common mistakes
- Who may handle refrigerant
- What to ask before you sign
- Sources
- Questions
At a glance
Sources: NAHB summary of the EPA final rule (May 2026); EPA AIM Act Technology Transitions program; US EPA, GreenChill regulatory context (archived page). Federal rules change; check the current EPA position before relying on any date here.
What changed, in plain terms
Equipment made or imported since 1 January 2025 uses lower-GWP A2L refrigerants (R-454B or R-32) instead of R-410A. An EPA rule finalized in May 2026, effective 27 July 2026, removed the 1 January 2026 cutoff, so contractors may install pre-2025 R-410A systems until that stock runs out.
The switch is driven by the federal AIM Act, which phases down hydrofluorocarbons (HFCs) with a high global warming potential (GWP). R-410A is one of those. R-454B and R-32 do the same job in an air conditioner with a much lower climate impact if they leak.
For a homeowner the practical effect is simple: a system quoted in 2026 will use either a new A2L refrigerant or older R-410A stock, and the two are not interchangeable. The refrigerant on your quote decides which coil, which parts and which service supply the system will need for its whole life.
The refrigerants you will see on quotes
| Refrigerant | Where you meet it | Safety class | What to know |
|---|---|---|---|
| R-22 | Systems installed before about 2010 | A1 (non-flammable) | Production and import ended in 2020; service only, from recovered or stockpiled supply |
| R-410A | Most systems from about 2010 to 2024 | A1 (non-flammable) | Pre-2025 stock may still be installed under the 2026 EPA rule |
| R-454B | New equipment since 2025 | A2L (lower flammability) | A refrigerant blend used in new equipment |
| R-32 | New equipment since 2025 | A2L (lower flammability) | A single-component refrigerant used in new equipment |
The "about" years are approximate transition periods, not rules. The data plate on the outdoor unit names the refrigerant; check yours before talking to a contractor.
What "A2L" means, and whether it should worry you
Refrigerants are classed by toxicity (A is lower) and flammability (1 is none, 2L is lower flammability, 3 is high). R-410A is A1. R-454B and R-32 are A2L: hard to ignite and slow-burning, but not completely non-flammable.
That is why equipment built for A2L refrigerants includes design changes such as leak detection in many indoor units, and why installation codes and manufacturer instructions add requirements for A2L systems. Those requirements are the installer’s job to know and follow, and they are another reason the work belongs with a licensed contractor.
For a homeowner, the useful question is not "is it safe?" in the abstract but "is this system installed to the manufacturer’s A2L instructions?" Ask the contractor to confirm it, and keep the installation manual with your paperwork.
No DIY refrigerant work
Under EPA’s Section 608 rules, refrigerant for these systems may be sold only to certified technicians or to employers of certified technicians. Mixing refrigerants or "topping up" with the wrong one can damage the system and void the warranty.
R-410A stock or a new A2L system: how to choose
Remaining R-410A stock
- Legal to install while pre-2025 stock lasts, per the 2026 EPA rule as summarized by NAHB.
- A refrigerant installers have worked with for years.
- May be priced to clear; ask.
- The open question is the cost and availability of R-410A for repairs over the system’s life, which no one can promise.
- Ask when the unit was manufactured; long-stored stock should still carry a full warranty.
New A2L system (R-454B or R-32)
- The direction the industry is moving, so service supply should keep growing.
- Current-generation equipment and controls.
- Costs more on the unit: Cold Factor Heating & Air (Flower Mound, TX) puts the change at about $700 on unit cost (DFW, 2026).
- Needs a coil designed for its refrigerant and installation to A2L requirements.
- Technicians are still gaining experience with it; ask about the installer’s A2L training.
There is no single right answer. If two quotes are close and both are installed well, the A2L system is the longer-horizon choice. If an R-410A system is meaningfully cheaper and you understand the repair-supply trade-off, it can still be reasonable. What matters more than the refrigerant is sizing and installation quality: ENERGY STAR material states that nearly half of heating and cooling equipment in US homes never performs to its advertised capacity and efficiency because of installation problems.
What the refrigerant change does to price
Published DFW ranges for a 3-ton central AC replacement on existing ducts run $5,500–$16,500, and 4 tons $7,500–$18,500. These are third-party published figures, not this site’s prices. Cold Factor Heating & Air (Flower Mound, TX), one of the sources behind those ranges, attributes about $700 of unit cost to the A2L change.
That figure is one contractor’s estimate, not a rule. A quote can also differ for reasons that are hard to see: whether the indoor coil is replaced, whether the line set is replaced, and whether the A2L installation needs extra parts. Ask for those lines to be shown separately.
| Line on the quote | Why it can differ with refrigerant | What to ask |
|---|---|---|
| Outdoor unit | A2L units are newer designs; R-410A stock may be discounted | Model number and manufacture date |
| Indoor coil | Must be designed for the same refrigerant | AHRI-matched pair, with the certificate number |
| Line set | May be reused or replaced depending on size and condition | Reuse or replace, and why |
| Leak detection or controls | Often built into A2L indoor units | Is anything extra required for this model? |
| Labor | Different handling and installation steps | Is labor itemized? |
The coil and line-set questions
An air conditioner is a matched pair: the outdoor unit and the indoor coil are rated together, and AHRI lists the combinations that have been certified. A new outdoor unit on a different refrigerant generally needs a new indoor coil designed for that refrigerant. Replacing only the outdoor unit is the most common way a "cheap" quote turns into a poorly performing system.
The line set, the pair of copper tubes between the units, is a judgment call. Some contractors reuse it after checking size and condition and flushing it; others replace it, particularly when it is buried in walls or the attic and hard to inspect. Neither is automatically wrong. Ask for the reason in writing.
Efficiency ratings also attach to the matched pair. Texas is in the DOE Southeast region. Since 1 January 2023 a split-system central AC under 45,000 BTU (about 3.75 tons) must be at least 14.3 SEER2 on the date it is installed; larger systems need 13.8. Split heat pumps need 14.3 SEER2 and 7.5 HSPF2 nationwide. An unmatched coil can leave a system below its rated efficiency.
If you still have an R-22 system
Production and import of virgin HCFC-22 (R-22) ended on 1 January 2020; existing R-22 systems may still be serviced with recovered or stockpiled refrigerant. R-22 equipment is now old; the repair-or-replace guide covers the decision.
A small repair that does not involve the refrigerant circuit, such as a capacitor or contactor, can still make sense. A leak or a failed compressor is usually the point to price a replacement, because recharging depends on a shrinking supply. Replacement means a new outdoor unit and a new coil for whichever refrigerant you choose, and often a review of the line set.
Avoid offers to convert an R-22 system to a "drop-in" substitute without a clear explanation of what it does to capacity, oil compatibility and warranty. Ask for the manufacturer’s position in writing.
Living with your choice: service over the years
An AC bought in 2026 will likely be serviced well into the 2030s, so think about the refrigerant you will be buying for repairs, not only the one in the box. The AIM Act phase-down limits how much new HFC refrigerant is produced over time, which is why the supply and price of R-410A for repairs is the main uncertainty with older stock.
Most repairs never touch the refrigerant: capacitors, contactors, fan motors and controls are the same kind of work either way. Refrigerant matters when there is a leak, a coil failure or a compressor replacement. Those are also the repairs where a homeowner most often faces a repair-or-replace decision.
- Keep the paperwork. Model numbers, the AHRI certificate, the refrigerant and charge on the data plate, and the warranty registration.
- Ask for leak checks during maintenance, so a small leak is found before a full recharge is needed.
- Ask any repair technician which refrigerant they are adding and how much, and expect it on the invoice.
Scenario: two quotes, two refrigerants
A hypothetical to show how to compare. Say a 1990s Plano two-story gets two quotes for a 3-ton replacement on existing ducts.
- Quote A offers an R-410A outdoor unit from remaining stock with a matching R-410A coil, line set reused after a flush.
- Quote B offers an R-454B system with a new coil and a new line set.
- Check both against the range. Each total should sit somewhere near the published DFW band for 3 tons, $5,500–$16,500. A total far outside it deserves an explanation.
- Normalize the scope. Quote B includes a new line set; ask Quote A what it would charge for the same, or why reuse is fine.
- Weigh the difference. If the gap is close to the published $700 unit-cost estimate plus the line set, the quotes are priced consistently, and the choice is about refrigerant horizon versus up-front cost.
- Confirm the essentials on both. Load calculation, AHRI number, manufacture date, permit and warranty registration.
The quote-comparison tool lays out up to three quotes side by side.
Common mistakes
- Not asking which refrigerant is quoted. It is often buried in the model number.
- Replacing only the outdoor unit. On a refrigerant change the coil must match.
- Assuming R-410A is now illegal. Under the 2026 rule summarized by NAHB, pre-2025 stock may still be installed.
- Assuming new is always worse value. The A2L premium may be modest compared with the system total.
- Topping up an R-22 or R-410A system with a different refrigerant. Never mix refrigerants.
- Hiring an unlicensed installer to save money. Refrigerant handling requires EPA certification, and Texas requires a TDLR license for the contractor.
Who may handle refrigerant
Under EPA’s Section 608 rules, refrigerant for these systems may be sold only to certified technicians or to employers of certified technicians. Texas licenses HVAC contractors through TDLR. Class A has no size limit; Class B covers cooling systems of 25 tons and under. Each license carries one endorsement; residential work is the Environmental Air endorsement. Contractors must hold liability insurance and renew with continuing education every year.
Check the contractor on the TDLR license lookup before signing, and confirm the city permit for the job on Dallas AC installation permits.
What to ask before you sign
- Which refrigerant does the quoted system use, R-410A, R-454B or R-32?
- If R-410A, when was the outdoor unit manufactured, and is the full warranty intact?
- Is the indoor coil new and matched to the outdoor unit? What is the AHRI certificate number?
- Will the line set be replaced or reused, and why?
- For an A2L system: is it installed to the manufacturer’s A2L instructions, and does the indoor unit include leak detection?
- Who on the crew holds EPA Section 608 certification?
- Is the permit included, and who registers the warranty?
For the wider list, see questions to ask an HVAC installer.
Sources
- NAHB summary of the EPA final rule (May 2026); EPA AIM Act Technology Transitions program (retrieved 2026-09-23)
- US EPA, GreenChill regulatory context (archived page) (retrieved 2026-10-20) — verify before relying on it
- US EPA, Section 608 refrigerant sales restriction (retrieved 2026-10-20) — verify before relying on it
- AHRI, "2023 Energy Efficiency Standards"; DOE regional standards (retrieved 2026-09-23)
- ENERGY STAR HVAC fact sheet (retrieved 2026-10-20) — verify before relying on it
- Texas Department of Licensing and Regulation, Air Conditioning and Refrigeration program (retrieved 2026-09-23)
- Cold Factor Heating & Air (Flower Mound, TX) (page dated 2026) (retrieved 2026-09-23)
- HVAC Services Pro (DFW) (page dated 2026-04-13) (retrieved 2026-09-23)
- HVAC Services Pro, DFW installation guide (page dated 2026-03-06) (retrieved 2026-09-23)
- HVACProjectCost.com, Dallas page (page dated 2026-08-02) (retrieved 2026-09-23)
Questions
Is an R-410A system still legal to install?
Pre-2025 R-410A stock may still be installed after EPA’s rule effective 27 July 2026, per the NAHB summary we cite. Verify the current rule before relying on it.
Is R-454B better than R-32?
Both are lower-GWP A2L refrigerants used in new equipment. Manufacturers choose one or the other. Compare the specific systems on efficiency, warranty and installation quality rather than the refrigerant alone.
Are A2L refrigerants dangerous at home?
They are classed as lower flammability, unlike non-flammable R-410A. Equipment and installation rules account for that. Ask the contractor to confirm the system is installed to the manufacturer’s A2L instructions.
Can I top up my R-22 system with a new refrigerant?
Not by mixing refrigerants. Ask a licensed contractor about options; a leaking R-22 system is usually the point to price a replacement.
Do I need a new coil with a new refrigerant?
Generally yes. The indoor coil is designed and rated with the outdoor unit for one refrigerant. Ask for the AHRI-matched pair.
How much more does an A2L system cost?
One DFW contractor guide puts the refrigerant change at about $700 on unit cost. Quotes vary with coil, line set and labor, so compare itemized quotes.
Next step
Free quote request
Get a quote to check against these numbers
- Tell us about the job. Service, ZIP, property and timing. The form says right away if your ZIP is outside the area.
- We check the license first. Requests go only to contractors whose TDLR air conditioning license we have matched on the state register. None is signed yet: if no checked contractor covers your ZIP, we email you and say so.
- Compare what comes back. Line the written quotes up in the quote-comparison tool.
No cost and no obligation. We are a publisher, not a contractor. Partner contractors will pay us for introductions; none is signed yet. How that works.
Request AC installation quotes
Free and no obligation. We pass a request on only to a contractor whose TDLR license we have checked and who covers your ZIP.